Inspection coming due, or failed a test? We’ll get your system back into compliance β€” On call until 11pm, seven days a week.

Protection That Has to Work the One Time It Matters

A fire sprinkler system spends years doing nothing β€” and then has to work perfectly in the ninety seconds that decide whether a fire stays in one room or takes the whole building. That’s the entire job: a system designed correctly, installed correctly, and tested often enough that you know it will do what it’s supposed to when it’s never mattered more.

We design, install, inspect, and repair fire suppression systems for commercial buildings, multi-unit residential properties, and homes across Central Pennsylvania. Whether you’re building new and need a system engineered to code, managing a property with an inspection coming due, or dealing with a system that failed a test, we handle the work β€” and the code paperwork and sign-offs that come with it.

Commercial & Industrial

Offices, retail, warehouses, and mixed-use buildings β€” systems designed, installed, and kept inspection-ready.

Multi-Unit Residential

Apartments, condos, and student housing where code requires suppression and inspections stay on schedule.

New Construction & Retrofits

Systems engineered into new builds, or added when an older building is renovated or expanded.

Fire Sprinkler Questions We Get Asked

How often does a fire sprinkler system need to be inspected?

Fire sprinkler systems follow a schedule of inspections and tests set by NFPA 25 and your local authority β€” some checks are quarterly, some annual, and some (like internal pipe or full-flow tests) run on multi-year cycles. The exact schedule depends on the system and the jurisdiction. We set you up with the right cadence and keep it on track, so you’re never caught out of compliance.

What's the difference between a wet and a dry sprinkler system?

A wet pipe system keeps water in the pipes at all times, ready to flow the instant a head opens β€” it’s the most common and the simplest. A dry pipe system holds pressurized air in the pipes and releases water only when a head activates, which keeps the lines from freezing in unheated spaces like parking garages, warehouses, and attics. We install and service both.

My building failed its fire sprinkler inspection β€” can you fix it?

Yes. A failed inspection comes with a list of deficiencies β€” a corroded valve, a painted-over head, low pressure, a bad gauge. We correct the deficiencies, retest, and file the certification so your system is back in compliance. If you’re facing a deadline from your inspector or insurer, tell us when you call.

Do you install systems in new homes and additions?

Yes. New residential construction increasingly requires fire sprinklers, and we design and install systems for new homes, additions, and renovations to the residential standard (NFPA 13D). For commercial and multi-unit projects, we work to the applicable NFPA 13 or 13R standard.

Call (814) 355-4841 or request service online. Design, installation, inspection, and repair for Central PA properties.